RFC1407-MIB DEFINITIONS ::= BEGIN

IMPORTS
        Gauge
                FROM RFC1155-SMI
        DisplayString, transmission
                FROM RFC1213-MIB
        OBJECT-TYPE
                FROM RFC-1212;

-- This MIB module uses the extended OBJECT-TYPE macro
-- as defined in RFC 1212.

        ds3  OBJECT IDENTIFIER ::= { transmission 30 }


-- The DS3/E3 Near End Group

-- Implementation of this group is mandatory for all
-- systems that attach to a DS3/E3 Interface.

-- The DS3/E3 Near End Group consists of four tables:
--    DS3/E3 Configuration
--    DS3/E3 Current
--    DS3/E3 Interval
--    DS3/E3 Total

-- the DS3/E3 Configuration

dsx3ConfigTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF Dsx3ConfigEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "The DS3/E3 Configuration table."
   ::= { ds3 5 }

dsx3ConfigEntry OBJECT-TYPE
    SYNTAX  Dsx3ConfigEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "An entry in the DS3/E3 Configuration table."
    INDEX   { dsx3LineIndex }
    ::= { dsx3ConfigTable 1 }

Dsx3ConfigEntry ::=
    SEQUENCE {
        dsx3LineIndex
            INTEGER,
        dsx3IfIndex
            INTEGER,
        dsx3TimeElapsed
            INTEGER,
        dsx3ValidIntervals
            INTEGER,
        dsx3LineType
            INTEGER,
        dsx3LineCoding
            INTEGER,
        dsx3SendCode
            INTEGER,
        dsx3CircuitIdentifier
            DisplayString,
        dsx3LoopbackConfig
            INTEGER,
        dsx3LineStatus
            INTEGER,
        dsx3TransmitClockSource
            INTEGER
}

dsx3LineIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "This object is the identifier of a DS3/E3
            Interface on a managed device.  If there is an
            ifEntry that is directly associated with this
            and only this DS3/E3 interface, it should have
            the same value as ifIndex.  Otherwise, number
            the dsx3LineIndices with an unique identifier
            following the rules of choosing a number that
            is greater than ifNumber and numbering the
            inside interfaces (e.g., equipment side) with
            even numbers and outside interfaces (e.g,
            network side) with odd numbers."
   ::= { dsx3ConfigEntry 1 }

dsx3IfIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "This value for this object is equal to the
            value of ifIndex from the Interfaces table of
            MIB II (RFC 1213)."
   ::= { dsx3ConfigEntry 2 }

dsx3TimeElapsed OBJECT-TYPE
    SYNTAX  INTEGER (0..899)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The number of seconds that have elapsed since
            the beginning of the near end current error-
            measurement period."
   ::= { dsx3ConfigEntry 3 }

dsx3ValidIntervals OBJECT-TYPE
    SYNTAX  INTEGER (0..96)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The number of previous near end intervals for
            which valid data was collected.  The value will be
            96 unless the interface was brought online within
            the last 24 hours, in which case the value will be
            the number of complete 15 minute near end
            intervals since the interface has been online."
    ::= { dsx3ConfigEntry 4 }

dsx3LineType OBJECT-TYPE
    SYNTAX  INTEGER {
                dsx3other(1),
                dsx3M23(2),
                dsx3SYNTRAN(3),
                dsx3CbitParity(4),
                dsx3ClearChannel(5),
                e3other(6),
                e3Framed(7),
                e3Plcp(8)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
            "This variable indicates the variety of DS3 C-bit
            or E3 application
            implementing this interface.  The type of
            interface affects the interpretation of the
            usage and error statistics.
            The rate of DS3 is 44.736 Mbps and E3 is
            34.368 Mbps.
            The dsx3ClearChannel value means that the C-bits
            are not used except for sending/receiving
            AIS.

            The values, in sequence, describe:

            TITLE:            SPECIFICATION:
            dsx3M23            ANSI T1.107-1988
            dsx3SYNTRAN        ANSI T1.107-1988
            dsx3CbitParity     ANSI T1.107a-1989
            dsx3ClearChannel   ANSI T1.102-1987
            e3Framed           CCITT G.751
            e3Plcp             ETSI T/NA(91)18."
    ::= { dsx3ConfigEntry 5 }

dsx3LineCoding OBJECT-TYPE
    SYNTAX  INTEGER {
                dsx3Other(1),
                dsx3B3ZS(2),
                e3HDB3(3)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
            "This variable describes the variety of Zero Code
            Suppression used on this interface, which in turn
            affects a number of its characteristics.

            dsx3B3ZS and e3HDB3 refer to the use of specified
            patterns of normal bits and bipolar violations
            which are used to replace sequences of zero bits
            of a specified length."
    ::= { dsx3ConfigEntry 6 }

dsx3SendCode OBJECT-TYPE
       SYNTAX  INTEGER {
               dsx3SendNoCode(1),
               dsx3SendLineCode(2),
               dsx3SendPayloadCode(3),
               dsx3SendResetCode(4),
               dsx3SendDS1LoopCode(5),
               dsx3SendTestPattern(6)
               }
       ACCESS  read-write
       STATUS  mandatory
       DESCRIPTION
            "This variable indicates what type of code is
            being sent across the DS3/E3 interface by the
            device.  (These are optional for E3 interfaces.)
            The values mean:

               dsx3SendNoCode
                   sending looped or normal data

               dsx3SendLineCode
                   sending a request for a line loopback

               dsx3SendPayloadCode
                   sending a request for a payload loopback
                   (i.e., all DS1/E1s in a DS3/E3 frame)

               dsx3SendResetCode
                   sending a loopback deactivation request

               dsx3SendDS1LoopCode
                   requesting to loopback a particular DS1/E1
                   within a DS3/E3 frame

               dsx3SendTestPattern
                   sending a test pattern."
       ::= { dsx3ConfigEntry 7 }

dsx3CircuitIdentifier OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..255))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
            "This variable contains the transmission vendor's
            circuit identifier, for the purpose of
            facilitating troubleshooting."
    ::= { dsx3ConfigEntry 8 }

dsx3LoopbackConfig OBJECT-TYPE
       SYNTAX  INTEGER {
                 dsx3NoLoop(1),
                 dsx3PayloadLoop(2),
                 dsx3LineLoop(3),
                 dsx3OtherLoop(4)
               }
       ACCESS  read-write
       STATUS  mandatory
       DESCRIPTION
          "This variable represents the loopback configuration
          of the DS3/E3 interface.
          The values mean:

          dsx3NoLoop
            Not in the loopback state.  A device that is
            not capable of performing a loopback on
            the interface shall always return this as
            it's value.

          dsx3PayloadLoop
            The received signal at this interface is looped
            through the device.
            Typically the received signal
            is looped back for retransmission after it has
            passed through the device's framing function.

          dsx3LineLoop
            The received signal at this interface does not
            go through the device (minimum penetration) but
            is looped back out.

          dsx3OtherLoop
            Loopbacks that are not defined here."
       ::= { dsx3ConfigEntry 9 }

dsx3LineStatus OBJECT-TYPE
    SYNTAX  INTEGER (1..1023)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
       "This variable indicates the
       Line Status of the interface.
       It contains loopback state information
       and failure state information.
       The dsx3LineStatus is a bit map represented
       as a sum, therefore,
       it can represent multiple failures
       and a loopback (see dsx3LoopbackConfig object
       for the type of loopback)
       simultaneously.
       The dsx3NoAlarm should be set if and only if
       no other flag is set.

       The various bit positions are:
          1     dsx3NoAlarm       No alarm present
          2     dsx3RcvRAIFailure Receiving Yellow/Remote
                Alarm Indication
          4     dsx3XmitRAIAlarm Transmitting Yellow/Remote
                Alarm Indication
          8     dsx3RcvAIS        Receiving AIS failure state
         16     dsx3XmitAIS       Transmitting AIS
         32     dsx3LOF           Receiving LOF failure state
         64     dsx3LOS           Receiving LOS failure state
        128     dsx3LoopbackState Looping the received signal
        256     dsx3RcvTestCode   Receiving a Test Pattern
        512     dsx3OtherFailure any line status not defined
                here"
    ::= { dsx3ConfigEntry 10 }

dsx3TransmitClockSource OBJECT-TYPE
    SYNTAX  INTEGER {
                loopTiming(1),
                localTiming(2),
                throughTiming(3)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
       "The source of Transmit Clock.
       is derived from the recovered receive clock of
       another DS3 interface."
    ::= { dsx3ConfigEntry 11 }


-- the DS3/E3 Current

-- The DS3/E3 current table contains various statistics being
-- collected for the current 15 minute interval.

dsx3CurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF Dsx3CurrentEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "The DS3/E3 Current table."
    ::= { ds3 6 }

dsx3CurrentEntry OBJECT-TYPE
    SYNTAX  Dsx3CurrentEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "An entry in the DS3/E3 Current table."
    INDEX   { dsx3CurrentIndex }
    ::= { dsx3CurrentTable 1 }

Dsx3CurrentEntry ::=
    SEQUENCE {
        dsx3CurrentIndex
            INTEGER,
        dsx3CurrentPESs
            Gauge,
        dsx3CurrentPSESs
            Gauge,
        dsx3CurrentSEFSs
            Gauge,
        dsx3CurrentUASs
            Gauge,
        dsx3CurrentLCVs
            Gauge,
        dsx3CurrentPCVs
            Gauge,
        dsx3CurrentLESs
            Gauge,
        dsx3CurrentCCVs
            Gauge,
        dsx3CurrentCESs
            Gauge,
        dsx3CurrentCSESs
            Gauge
    }

dsx3CurrentIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The index value which uniquely identifies the
            DS3/E3 interface to which this entry is
            applicable.  The interface identified by a
            particular value of this index is the same
            interface as identified by the same value an
            dsx3LineIndex object instance."
    ::= { dsx3CurrentEntry 1 }

dsx3CurrentPESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of P-bit
            Errored Seconds, encountered by a DS3 interface in
            the current 15 minute interval."
    ::= { dsx3CurrentEntry 2 }

dsx3CurrentPSESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of P-bit
            Severely Errored Seconds, encountered by a DS3
            interface in the current 15 minute interval."
    ::= { dsx3CurrentEntry 3 }

dsx3CurrentSEFSs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of
            Severely Errored Framing Seconds, encountered by a
            DS3/E3 interface in the current 15 minute
            interval."
    ::= { dsx3CurrentEntry 4 }

dsx3CurrentUASs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of
            Unavailable Seconds, encountered by a DS3
            interface in the current 15 minute interval."
    ::= { dsx3CurrentEntry 5 }

dsx3CurrentLCVs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of Line
            Coding Violations encountered by a DS3/E3
            interface in the current 15 minute interval."
    ::= { dsx3CurrentEntry 6 }

dsx3CurrentPCVs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of P-bit
            Coding Violations, encountered by a DS3 interface
            in the current 15 minute interval."
    ::= { dsx3CurrentEntry 7 }

dsx3CurrentLESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The number of Line Errored Seconds encountered by
            a DS3/E3 interface in the current 15 minute
            interval."
    ::= { dsx3CurrentEntry 8 }

dsx3CurrentCCVs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The number of C-bit Coding Violations encountered
            by a DS3 interface in the current 15 minute
            interval."
    ::= { dsx3CurrentEntry 9 }

dsx3CurrentCESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The number of C-bit Errored Seconds encountered
            by a DS3 interface in the current 15 minute
            interval."
    ::= { dsx3CurrentEntry 10 }

dsx3CurrentCSESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The number of C-bit Severely Errored Seconds
            encountered by a DS3 interface in the current 15
            minute interval."
    ::= { dsx3CurrentEntry 11 }


-- the DS3/E3 Interval

-- The DS3/E3 Interval Table contains various statistics
-- collected by each DS3/E3 Interface over the previous 24
-- hours of operation.  The past 24 hours are broken into 96
-- completed 15 minute intervals.

dsx3IntervalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF Dsx3IntervalEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "The DS3/E3 Interval table."
    ::= { ds3 7 }

dsx3IntervalEntry OBJECT-TYPE
    SYNTAX  Dsx3IntervalEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "An entry in the DS3/E3 Interval table."
    INDEX   { dsx3IntervalIndex, dsx3IntervalNumber }
    ::= { dsx3IntervalTable 1 }

Dsx3IntervalEntry ::=
    SEQUENCE {
        dsx3IntervalIndex
            INTEGER,
        dsx3IntervalNumber
            INTEGER,
        dsx3IntervalPESs
            Gauge,
        dsx3IntervalPSESs
            Gauge,
        dsx3IntervalSEFSs
            Gauge,
        dsx3IntervalUASs
            Gauge,
        dsx3IntervalLCVs
            Gauge,
        dsx3IntervalPCVs
            Gauge,
        dsx3IntervalLESs
            Gauge,
        dsx3IntervalCCVs
            Gauge,
        dsx3IntervalCESs
            Gauge,
        dsx3IntervalCSESs
            Gauge
    }

dsx3IntervalIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The index value which uniquely identifies the
            DS3/E3 interface to which this entry is
            applicable.  The interface identified by a
            particular value of this index is the same
            interface as identified by the same value an
            dsx3LineIndex object instance."
    ::= { dsx3IntervalEntry 1 }

dsx3IntervalNumber OBJECT-TYPE
    SYNTAX  INTEGER (1..96)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "A number between 1 and 96, where 1 is the most
            recently completed 15 minute interval and 96 is
            the least recently completed 15 minutes interval
            (assuming that all 96 intervals are valid)."
    ::= { dsx3IntervalEntry 2 }

dsx3IntervalPESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of P-bit
            Errored Seconds, encountered by a DS3 interface in
            one of the previous 96, individual 15 minute,
            intervals."
    ::= { dsx3IntervalEntry 3 }

dsx3IntervalPSESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of P-bit
            Severely Errored Seconds, encountered by a DS3
            interface in one of the previous 96, individual 15
            minute, intervals."
    ::= { dsx3IntervalEntry 4 }

dsx3IntervalSEFSs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of
            Severely Errored Framing Seconds, encountered by a
            DS3/E3 interface in one of the previous 96,
            individual 15 minute, intervals."
    ::= { dsx3IntervalEntry 5 }

dsx3IntervalUASs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of
            Unavailable Seconds, encountered by a DS3
            interface in one of the previous 96, individual 15
            minute, intervals."
    ::= { dsx3IntervalEntry 6 }

dsx3IntervalLCVs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of Line
            Coding Violations encountered by a DS3/E3
            interface in one of the previous 96, individual 15
            minute, intervals."
    ::= { dsx3IntervalEntry 7 }

dsx3IntervalPCVs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of P-bit
            Coding Violations, encountered by a DS3 interface
            in one of the previous 96, individual 15 minute,
            intervals."
    ::= { dsx3IntervalEntry 8 }

dsx3IntervalLESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The number of Line Errored  Seconds  (BPVs  or
         illegal  zero  sequences) encountered by a DS3/E3
         interface in one of the previous 96, individual
         15 minute, intervals."
    ::= { dsx3IntervalEntry 9 }

dsx3IntervalCCVs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The number of C-bit Coding Violations encountered
            by a DS3 interface in one of the previous 96,
            individual 15 minute, intervals."
    ::= { dsx3IntervalEntry 10 }

dsx3IntervalCESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The number of C-bit Errored Seconds encountered
            by a DS3 interface in one of the previous 96,
            individual 15 minute, intervals."
    ::= { dsx3IntervalEntry 11 }

dsx3IntervalCSESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The number of C-bit Severely Errored Seconds
            encountered by a DS3 interface in one of the
            previous 96, individual 15 minute, intervals."
    ::= { dsx3IntervalEntry 12 }


-- the DS3/E3 Total

-- The DS3/E3 Total Table contains the cumulative sum of the
-- various statistics for the 24 hour period preceding the
-- current interval.

dsx3TotalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF Dsx3TotalEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "The DS3/E3 Total table.  24 hour interval."
    ::= { ds3 8 }

dsx3TotalEntry OBJECT-TYPE
    SYNTAX  Dsx3TotalEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "An entry in the DS3/E3 Total table."
    INDEX   { dsx3TotalIndex }
    ::= { dsx3TotalTable 1 }

Dsx3TotalEntry ::=
    SEQUENCE {
        dsx3TotalIndex
            INTEGER,
        dsx3TotalPESs
            Gauge,
        dsx3TotalPSESs
            Gauge,
        dsx3TotalSEFSs
            Gauge,
        dsx3TotalUASs
            Gauge,
        dsx3TotalLCVs
            Gauge,
        dsx3TotalPCVs
            Gauge,
        dsx3TotalLESs
            Gauge,
        dsx3TotalCCVs
            Gauge,
        dsx3TotalCESs
            Gauge,
        dsx3TotalCSESs
            Gauge
    }

dsx3TotalIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The index value which uniquely identifies the
            DS3/E3 interface to which this entry is
            applicable.  The interface identified by a
            particular value of this index is the same
            interface as identified by the same value an
            dsx3LineIndex object instance."
    ::= { dsx3TotalEntry 1 }

dsx3TotalPESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of P-bit
            Errored Seconds, encountered by a DS3 interface in
            the previous 24 hour interval"
    ::= { dsx3TotalEntry 2 }

dsx3TotalPSESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of P-bit
            Severely Errored Seconds, encountered by a DS3
            interface in the previous 24 hour interval."
    ::= { dsx3TotalEntry 3 }

dsx3TotalSEFSs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of
            Severely Errored Framing Seconds, encountered by a
            DS3/E3 interface in the previous 24 hour
            interval."
    ::= { dsx3TotalEntry 4 }

dsx3TotalUASs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of
            Unavailable Seconds, encountered by a DS3
            interface in the previous 24 hour interval."
    ::= { dsx3TotalEntry 5 }

dsx3TotalLCVs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of Line
            Coding Violations encountered by a DS3/E3
            interface in the previous 24 hour interval."
    ::= { dsx3TotalEntry 6 }

dsx3TotalPCVs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of P-bit
            Coding Violations, encountered by a DS3 interface
            in the previous 24 hour interval."
    ::= { dsx3TotalEntry 7 }

dsx3TotalLESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The number of Line Errored  Seconds  (BPVs  or
         illegal  zero  sequences) encountered by a DS3/E3
         interface in the previous 24 hour interval."
    ::= { dsx3TotalEntry 8 }

dsx3TotalCCVs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The number of C-bit Coding Violations encountered
            by a DS3 interface in the previous 24 hour
            interval."
    ::= { dsx3TotalEntry 9 }

dsx3TotalCESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The number of C-bit Errored Seconds encountered
            by a DS3 interface in the previous 24 hour
            interval."
    ::= { dsx3TotalEntry 10 }

dsx3TotalCSESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The number of C-bit Severely Errored Seconds
            encountered by a DS3 interface in the previous 24
            hour interval."
    ::= { dsx3TotalEntry 11 }


-- The DS3 Far End Group

-- Implementation of this group is optional for all systems
-- that attach to a DS3 Interface.
-- However, only C-bit Parity and SYNTRAN DS3 applications
-- have the capability (option) of providing this information.

-- The DS3 Far End Group consists of four tables:
--   DS3 Far End Configuration
--   DS3 Far End Current
--   DS3 Far End Interval
--   DS3 Far End Total


-- The DS3 Far End Configuration Table contains
-- configuration information
-- reported in the C-bits from the remote end.

dsx3FarEndConfigTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF Dsx3FarEndConfigEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
       "The DS3 Far End Configuration table."
    ::= { ds3 9 }

dsx3FarEndConfigEntry OBJECT-TYPE
    SYNTAX  Dsx3FarEndConfigEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
         "An entry in the DS3 Far End Configuration table."
    INDEX   { dsx3FarEndLineIndex }
    ::= { dsx3FarEndConfigTable 1 }

Dsx3FarEndConfigEntry ::=
    SEQUENCE {
        dsx3FarEndLineIndex
            INTEGER,
        dsx3FarEndEquipCode
            DisplayString,
        dsx3FarEndLocationIDCode
            DisplayString,
        dsx3FarEndFrameIDCode
            DisplayString,
        dsx3FarEndUnitCode
            DisplayString,
        dsx3FarEndFacilityIDCode
            DisplayString
     }

dsx3FarEndLineIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
         "The index value which uniquely identifies the
         DS3 interface
         to which this entry is applicable.  The
         interface identified by a particular value of
         this index is the same interface as identified
         by the same value an dsx3LineIndex object
         instance."
   ::= { dsx3FarEndConfigEntry 1 }

dsx3FarEndEquipCode OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..10))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
          "This is the Far End Equipment Identification code
          that describes the specific piece of equipment.
          It is sent within the Path
          Identification Message."
    ::= { dsx3FarEndConfigEntry 2 }

dsx3FarEndLocationIDCode OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..11))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
          "This is the Far End Location Identification code
          that describes the specific location of the
          equipment.
          It is sent within the Path
          Identification Message."
    ::= { dsx3FarEndConfigEntry 3 }

dsx3FarEndFrameIDCode OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..10))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
          "This is the Far End Frame Identification code
          that identifies where the equipment is located
          within a building at a given location.
          It is sent within the Path
          Identification Message."
    ::= { dsx3FarEndConfigEntry 4 }

dsx3FarEndUnitCode OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..6))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
          "This is the Far End code
          that identifies the equipment location within a bay.
          It is sent within the Path
          Identification Message."
    ::= { dsx3FarEndConfigEntry 5 }

dsx3FarEndFacilityIDCode OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..38))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
          "This code identifies a specific Far End DS3 path.
          It is sent within the Path
          Identification Message."
    ::= { dsx3FarEndConfigEntry 6 }


-- The DS3 Far End Current

-- The DS3 Far End Current table contains various statistics
-- being collected for the current 15 minute interval.
-- The statistics are collected from the far end block error
-- code within the C-bits.

dsx3FarEndCurrentTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF Dsx3FarEndCurrentEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "The DS3 Far End Current table."
    ::= { ds3 10 }

dsx3FarEndCurrentEntry OBJECT-TYPE
    SYNTAX  Dsx3FarEndCurrentEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "An entry in the DS3 Far End Current table."
    INDEX   { dsx3FarEndCurrentIndex }
    ::= { dsx3FarEndCurrentTable 1 }

Dsx3FarEndCurrentEntry ::=
    SEQUENCE {
        dsx3FarEndCurrentIndex
            INTEGER,
        dsx3FarEndTimeElapsed
            INTEGER,
        dsx3FarEndValidIntervals
            INTEGER,
        dsx3FarEndCurrentCESs
            Gauge,
        dsx3FarEndCurrentCSESs
            Gauge,
        dsx3FarEndCurrentCCVs
            Gauge,
        dsx3FarEndCurrentUASs
            Gauge
    }

 dsx3FarEndCurrentIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The index value which uniquely identifies the
            DS3 interface
            to which this entry is applicable.  The interface
            identified by a particular value of this index is
            the same interface as identified by the same value
            an dsx3LineIndex object instance."
    ::= { dsx3FarEndCurrentEntry 1 }

dsx3FarEndTimeElapsed OBJECT-TYPE
    SYNTAX  INTEGER (0..899)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The number of seconds that have elapsed since the
            beginning of the far end current error-measurement
            period."
    ::= { dsx3FarEndCurrentEntry 2 }

dsx3FarEndValidIntervals OBJECT-TYPE
    SYNTAX  INTEGER (0..96)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The number of previous far end intervals for
            which valid data was collected.  The value will be
            96 unless the interface was brought online within
            the last 24 hours, in which case the value will be
            the number of complete 15 minute far end intervals
            since the interface has been online."
    ::= { dsx3FarEndCurrentEntry 3 }

dsx3FarEndCurrentCESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of Far
            Far End C-bit Errored Seconds encountered by a DS3
            interface in the current 15 minute interval."
    ::= { dsx3FarEndCurrentEntry 4 }

dsx3FarEndCurrentCSESs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of
            Far End C-bit Severely Errored Seconds
            encountered by a DS3 interface in the current 15
            minute interval."
    ::= { dsx3FarEndCurrentEntry 5 }

dsx3FarEndCurrentCCVs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of
            Far End C-bit Coding Violations reported via
            the far end block error count
            encountered by a
            DS3 interface in the current 15 minute interval."
    ::= { dsx3FarEndCurrentEntry 6 }

dsx3FarEndCurrentUASs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of
            Far End unavailable seconds
            encountered by a
            DS3 interface in the current 15 minute interval."
    ::= { dsx3FarEndCurrentEntry 7 }


-- The DS3 Far End Interval

-- The DS3 Far End Interval Table contains various statistics
-- collected by each DS3 interface over the previous 24
-- hours of operation.  The past 24 hours are broken into 96
-- completed 15 minute intervals.

dsx3FarEndIntervalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF Dsx3FarEndIntervalEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
           "The DS3 Far End Interval table."
    ::= { ds3 11 }

dsx3FarEndIntervalEntry OBJECT-TYPE
    SYNTAX  Dsx3FarEndIntervalEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
          "An entry in the DS3 Far
          End Interval table."
    INDEX   { dsx3FarEndIntervalIndex,
              dsx3FarEndIntervalNumber }
    ::= { dsx3FarEndIntervalTable 1 }

Dsx3FarEndIntervalEntry ::=
    SEQUENCE {
         dsx3FarEndIntervalIndex
              INTEGER,
         dsx3FarEndIntervalNumber
              INTEGER,
         dsx3FarEndIntervalCESs
              Gauge,
         dsx3FarEndIntervalCSESs
              Gauge,
         dsx3FarEndIntervalCCVs
              Gauge,
         dsx3FarEndIntervalUASs
              Gauge
    }

dsx3FarEndIntervalIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The index value which uniquely identifies the
            DS3 interface
            to which this entry is applicable.  The
            interface identified by a particular value of
            this index is the same interface as identified
            by the same value an dsx3LineIndex object
            instance."
    ::= { dsx3FarEndIntervalEntry 1 }

dsx3FarEndIntervalNumber OBJECT-TYPE
   SYNTAX  INTEGER (1..96)
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
          "A number between 1 and 96, where 1 is the most
          recently completed 15 minute interval and 96 is
          the least recently completed 15 minutes
          interval (assuming that all 96 intervals are
          valid)."
   ::= { dsx3FarEndIntervalEntry 2 }

dsx3FarEndIntervalCESs OBJECT-TYPE
   SYNTAX  Gauge
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
           "The counter associated with the number of
            Far End C-bit Errored Seconds encountered
            by a DS3 interface in one of the previous 96,
            individual 15 minute, intervals."
  ::= { dsx3FarEndIntervalEntry 3 }

dsx3FarEndIntervalCSESs OBJECT-TYPE
   SYNTAX  Gauge
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
           "The counter associated with the number of
           Far End C-bit Severely Errored Seconds
           encountered by a DS3 interface in one of the
           previous 96, individual 15 minute, intervals."
  ::= { dsx3FarEndIntervalEntry 4 }

dsx3FarEndIntervalCCVs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of
            Far End C-bit Coding Violations reported via
            the far end block error count
            encountered by a
            DS3 interface in one of the previous 96,
            individual 15 minute, intervals."
    ::= { dsx3FarEndIntervalEntry 5 }

dsx3FarEndIntervalUASs OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The counter associated with the number of
            Far End unavailable seconds
            encountered by a
            DS3 interface in one of the previous 96,
            individual 15 minute, intervals."
    ::= { dsx3FarEndIntervalEntry 6 }


-- The DS3 Far End Total

-- The DS3 Far End Total Table contains the cumulative sum
-- of the various statistics for the 24 hour period preceding
-- the current interval.

dsx3FarEndTotalTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF Dsx3FarEndTotalEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "The DS3 Far End Total table.  24 hour interval."
    ::= { ds3 12 }

dsx3FarEndTotalEntry OBJECT-TYPE
    SYNTAX  Dsx3FarEndTotalEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "An entry in the DS3 Far End Total table."
    INDEX   { dsx3FarEndTotalIndex }
    ::= { dsx3FarEndTotalTable 1 }

Dsx3FarEndTotalEntry ::=
    SEQUENCE {
        dsx3FarEndTotalIndex
            INTEGER,
        dsx3FarEndTotalCESs
            Gauge,
        dsx3FarEndTotalCSESs
            Gauge,
        dsx3FarEndTotalCCVs
            Gauge,
        dsx3FarEndTotalUASs
            Gauge
    }

dsx3FarEndTotalIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..65535)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The index value which uniquely identifies the
            DS3 interface
            to which this entry is applicable.  The interface
            identified by a particular value of this index is
            the same interface as identified by the same value
            an dsx3LineIndex object instance."
    ::= { dsx3FarEndTotalEntry 1 }

dsx3FarEndTotalCESs OBJECT-TYPE
   SYNTAX  Gauge
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
           "The counter associated with the number of Far
           End C-bit Errored Seconds encountered by a DS3
           interface in the previous 24 hour interval."
   ::= { dsx3FarEndTotalEntry 2 }

dsx3FarEndTotalCSESs OBJECT-TYPE
   SYNTAX  Gauge
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
           "The counter associated with the number of
           Far End C-bit Severely Errored Seconds
           encountered by a DS3 interface in the previous 24
           hour interval."
   ::= { dsx3FarEndTotalEntry 3 }

dsx3FarEndTotalCCVs OBJECT-TYPE
   SYNTAX  Gauge
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
           "The counter associated with the number of
           Far End C-bit Coding Violations reported via the
           far end block error count
           encountered by a
           DS3 interface in the previous 24 hour interval."
   ::= { dsx3FarEndTotalEntry 4 }

dsx3FarEndTotalUASs OBJECT-TYPE
   SYNTAX  Gauge
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
           "The counter associated with the number of
           Far End unavailable seconds
           encountered by a
           DS3 interface in the previous 24 hour interval."
   ::= { dsx3FarEndTotalEntry 5 }


-- the DS3/E3 Fractional Group

-- Implementation of this group is optional.  It is designed
-- for those systems dividing a DS3/E3 into channels
-- containing different data streams that are of local
-- interest.

-- The DS3/E3 fractional table identifies which DS3/E3
-- channels associated with a CSU are being used to
-- support a logical interface, i.e., an entry in the
-- interfaces table from the Internet-standard MIB.

-- For example, consider a DS3 device with 4 high speed links
-- carrying router traffic, a feed for voice, a feed for
-- video, and a synchronous channel for a non-routed
-- protocol.
-- We might describe the allocation of channels, in the
-- dsx3FracTable, as follows:

-- dsx3FracIfIndex.2. 1 = 3    dsx3FracIfIndex.2.15 = 4
-- dsx3FracIfIndex.2. 2 = 3    dsx3FracIfIndex.2.16 = 6
-- dsx3FracIfIndex.2. 3 = 3    dsx3FracIfIndex.2.17 = 6
-- dsx3FracIfIndex.2. 4 = 3    dsx3FracIfIndex.2.18 = 6
-- dsx3FracIfIndex.2. 5 = 3    dsx3FracIfIndex.2.19 = 6
-- dsx3FracIfIndex.2. 6 = 3    dsx3FracIfIndex.2.20 = 6
-- dsx3FracIfIndex.2. 7 = 4    dsx3FracIfIndex.2.21 = 6
-- dsx3FracIfIndex.2. 8 = 4    dsx3FracIfIndex.2.22 = 6
-- dsx3FracIfIndex.2. 9 = 4    dsx3FracIfIndex.2.23 = 6
-- dsx3FracIfIndex.2.10 = 4    dsx3FracIfIndex.2.24 = 6
-- dsx3FracIfIndex.2.11 = 4    dsx3FracIfIndex.2.25 = 6
-- dsx3FracIfIndex.2.12 = 5    dsx3FracIfIndex.2.26 = 6
-- dsx3FracIfIndex.2.13 = 5    dsx3FracIfIndex.2.27 = 6
-- dsx3FracIfIndex.2.14 = 5    dsx3FracIfIndex.2.28 = 6

-- For dsx3M23, dsx3SYNTRAN, dsx3CbitParity, and
-- dsx3ClearChannel there are 28 legal channels, numbered 1
-- through 28.

-- For e3Framed there are 16 legal channels,
-- numbered 1 through 16.  The channels (1..16) correspond
-- directly to the equivalently numbered time-slots.

dsx3FracTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF Dsx3FracEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
       "The DS3 Fractional table."
    ::= { ds3 13 }

dsx3FracEntry OBJECT-TYPE
     SYNTAX  Dsx3FracEntry
     ACCESS  not-accessible
     STATUS  mandatory
     DESCRIPTION
        "An entry in the DS3 Fractional table."
    INDEX   { dsx3FracIndex, dsx3FracNumber }
    ::= { dsx3FracTable 1 }

Dsx3FracEntry ::=
    SEQUENCE {
        dsx3FracIndex
            INTEGER,
        dsx3FracNumber
            INTEGER,
        dsx3FracIfIndex
            INTEGER
    }


dsx3FracIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..'7fffffff'h)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
       "The index value which uniquely identifies  the
       DS3  interface  to which this entry is applicable
       The interface identified by a  particular
       value  of  this  index is the same interface as
       identified by the same value  an  dsx3LineIndex
       object instance."
   ::= { dsx3FracEntry 1 }

dsx3FracNumber OBJECT-TYPE
    SYNTAX  INTEGER (1..31)
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
       "The channel number for this entry."
   ::= { dsx3FracEntry 2 }

dsx3FracIfIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..'7fffffff'h)
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
       "An index value that uniquely identifies an
       interface.  The interface identified by a particular
       value of this index is the same  interface
       as  identified by the same value an ifIndex
       object instance. If no interface is currently using
       a channel, the value should be zero.  If a
       single interface occupies more  than  one  time
       slot,  that ifIndex value will be found in multiple
       time slots."
   ::= { dsx3FracEntry 3 }



END